Micro Motion Coriolis Mass Flow and Density sensors, offer superior mass, density, and volume flow accuracy, and are calibrated using gravimetric calibration stands in Ede, The Netherlands.
...
The European Flow Center, based in Ede, The Netherlands, houses three calibration stands, named SSF1B, SSF2A, and SSF3A.
SSF stands for Standing Start Finish.
The graphic schematics are shown below.
On calibration stand SSF1B calibration is done for sensor sizes 3 to 15 mm nominal line size.
Calibration stand SSF2A supports calibrations from 15 to 80 mm and calibration stand SSF3A supports calibrations for line sizes 50 mm and above.
The Low flow product family is calibrated in the Global Center in Boulder, Colorado, USA.
Calibration is done according to the Static Start Stop‐standard ISO 10790 or to the ISO 17025 Standard using the Static Start Stop method.
The calibration procedures are equal for all three stands.
The base calibration principle used is gravimetric.
To ensure the highest quality calibration, Emerson Process Management Flow has invested significant resources in a tailor made calibration software and hardware solution.
This solution also verifies the performance of each sensor to the specifications for that specific sensor family.
Micro Motion Coriolis Mass Flow and Density sensors, offer superior mass, density, and volume flow accuracy, and are calibrated using gravimetric calibration stands in Ede, The Netherlands.
...
The European Flow Center, based in Ede, The Netherlands, houses three calibration stands, named SSF1B, SSF2A, and SSF3A.
SSF stands for Standing Start Finish.
The graphic schematics are shown below.
On calibration stand SSF1B calibration is done for sensor sizes 3 to 15 mm nominal line size.
Calibration stand SSF2A supports calibrations from 15 to 80 mm and calibration stand SSF3A supports calibrations for line sizes 50 mm and above.
The Low flow product family is calibrated in the Global Center in Boulder, Colorado, USA.
Calibration is done according to the Static Start Stop‐standard ISO 10790 or to the ISO 17025 Standard using the Static Start Stop method.
The calibration procedures are equal for all three stands.
The base calibration principle used is gravimetric.
To ensure the highest quality calibration, Emerson Process Management Flow has invested significant resources in a tailor made calibration software and hardware solution.
This solution also verifies the performance of each sensor to the specifications for that specific sensor family.
Proposed translations
(Russian)
4 | Статичный старт/стоп | Oleg Polygaloff |
3 +1 | см. | Lilia_vertaler |
3 | стандарт старта/пуска из неподвижного состояния - остановки | Andrey Svitanko |
Proposed translations
1 hr
Selected
Статичный старт/стоп
http://www.askue-spektr.ru/base/teploschetchik_multical_402/...
--------------------------------------------------
Note added at 1 час (2015-04-03 12:10:12 GMT)
--------------------------------------------------
Только скорее "статический".. Есть такой метод испытаний расходомеров и счетчиков..
--------------------------------------------------
Note added at 1 час (2015-04-03 12:10:12 GMT)
--------------------------------------------------
Только скорее "статический".. Есть такой метод испытаний расходомеров и счетчиков..
4 KudoZ points awarded for this answer.
10 mins
стандарт старта/пуска из неподвижного состояния - остановки
Думаю, что тоже самое.
между start и stop должно быть "-" или "/"
--------------------------------------------------
Note added at 12 мин (2015-04-03 10:47:58 GMT)
--------------------------------------------------
Ну да, точно, вот:
http://www.google.st/patents/CN101556181A?cl=un
"Composite static start-stop method mass flowmeter calibration system"
http://www.google.com/patents/US20120179357
"This approach is known as static start/stop"
и т.д.
между start и stop должно быть "-" или "/"
--------------------------------------------------
Note added at 12 мин (2015-04-03 10:47:58 GMT)
--------------------------------------------------
Ну да, точно, вот:
http://www.google.st/patents/CN101556181A?cl=un
"Composite static start-stop method mass flowmeter calibration system"
http://www.google.com/patents/US20120179357
"This approach is known as static start/stop"
и т.д.
+1
37 mins
см.
Метод измерений с начальными и конечными данными при нулевом расходе - стандарт...
Static start/stop — data collection starts and stops at zero flow conditions.
In this case, the run time shall be sufficiently long to account for errors induced by flow rate variations at the start and end of the run.
https://law.resource.org/pub/in/bis/S01/is.15672.2006.pdf - стр. 19
Static start/stop — data collection starts and stops at zero flow conditions.
In this case, the run time shall be sufficiently long to account for errors induced by flow rate variations at the start and end of the run.
https://law.resource.org/pub/in/bis/S01/is.15672.2006.pdf - стр. 19